Specifications

Model Chambers Thermometer Temperature
regulation
Burner type Max. volume Max. capacity Lorry pay load Tare weight Gas
consumption
AF20 1 Analogue* Manual* Direct flame* 1 m3 2.2 t 3.1 t 870 kg 1 kg/h
AF25 1 Analogue* Manual* Direct flame* 1.4 m3 3.1 t 4.0 t 950 kg 1 kg/h
AF50 1 Digital Automatic Lamella 2.8 m3 6.2 t 7.7 t 1500 kg 2 kg/h
AF50/2K 2 Digital Automatic Lamella 3.4 m3 7.5 t 9.2 t 1700 kg 2 kg/h
AF75 1 Digital Automatic Lamella 4.2 m3 9.3 t 11.1 t 1800 kg 3 kg/h
AF75/2K 2 Digital Automatic Lamella 5.1 m3 11.4 t 13.4 t 2000 kg 3 kg/h
AF100 1 Digital Automatic Lamella 5.5 m3 12.2 t 14.3 t 2100 kg 4 kg/h
AF100/2K 2 Digital Automatic Lamella 6.9 m3 15.5 t 17.9 t 2350 kg 4 kg/h
AF100/H 1 Digital Automatic Lamella 7.5 m3 16.7 t 18.9 t 2200 kg 5 kg/h
AF100/2KH 2 Digital Automatic Lamella 8.8 m3 19.6 t 22.0 t 2450 kg 5 kg/h

* The AF-20 and AF-25 can be equipped with automatic thermostatic temperature control and lametta burners

Sizes

Model A B C D E F G H I J
AF20 2880 470 1610 640 410 1770 0 1245 1500 1740
AF25 2880 470 1610 640 410 1770 0 1445 1500 1940
AF50 3820 680 2290 850 455 2450 250 1620 2000 1930
AF50/2K 3820 680 2290 850 455 2450 250 1700 2000 2010
AF75 4820 680 3290 850 455 3450 250 1620 2000 1930
AF75/2K 4820 680 3290 850 455 3450 250 1700 2000 2010
AF100 5820 680 4290 850 455 4450 250 1620 2000 1930
AF100/2K 5820 680 4290 850 455 4450 250 1700 2000 2010
AF100/H 5820 680 4290 850 455 4450 250 1950 2000 2260
AF100/2KH 5820 680 4290 850 455 4450 250 1950 2000 2260